Thermazone Roofboard is a Polyisocyanurate (PIR) rigid insulation faced on both sides with a mineralised glass tissue.

Key Features

  • Suitable for a range of mechanically fixed and adhered single-ply waterproofing systems

  • PIR core for high thermal conductivity value

  • High compressive strength of ≥ 150 kPa (@10% compression)

Unable to find what you were looking for?

Do you have questions about the product, systems or anything else? 
We're here to help - contact us and one of our experts will help you.

CE Information
Harmonised Standard

EN 13165:2012+A2:2016 - Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification

Intended use

PIR insulation for use within a multilayer system

Name and registered address of the manufacturer

BMI Group UK Limited, BMI House, 2 Pitfield, Kiln Farm, Milton Keynes, MK11 3LW United Kingdom

Notified Body 1 (Code)

1136

Notified Body 2 (Code)

2137

System/s of AVCP

System 3

Website hosting the DoP

bmigroup.com/uk

Dimensions
Base Unit Of Measure

PCE

Height

0.060 m

Length

1.200 m

Volume

0.043 m³

Width

0.600 m

Insulation characteristics
Base Unit Of Measure

PCE

Compressive strength

150 kPa (@ 10% compression) kPa

Core

Polyisocyanurate (PIR)

Edge profile

Square

Insulant type

PIR (Polyisocyanurate)

Pack size (No. of boards)

8 boards per pack

Thermal conductivity / Lambda (K) W/m·K

0.024 - 0.027 W/m.K (depending on thickness)

Material Characteristics
Durability

The product is designed to last the lifetime of the building

Material Type

Insulation Board

Method of application

Insulation boards should be installed in accordance with the manufacturer’s guidelines.

Membrane Characteristics
Lower surface

Mineral glass tissue

Upper surface

Mineral glass tissue

Safety information
Reaction to fire

Euroclass F in accordance with EN 13501-1

Technical standards and references
CE Marking (harmonised standard(s))

The Certificate holder has taken the responsibility of CE marking the product, in accordance with harmonised European Standard BS EN 13165 : 2012.

Certification

BBA certificate number 23/6935 (PS3).

Codes of Practice

The roof construction and design should comply with BS 6229 (Code of Practice for Flat Roofs with Continuous Supported Coverings).

Designated application

Thermazone Roofboards are intended for use as a thermal insulation layer, and used in conjunction with all types of waterproofing systems, including heat-activated self-adhesive systems and mechanically fixed and adhered single-ply systems.

Relevant standards

EN 12667

Uniclass reference

Pr_25_31_28_65

Weight
Gross Weight

1.779 kg

CE Information

Harmonised Standard

EN 13165:2012+A2:2016 - Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification

Intended use

PIR insulation for use within a multilayer system

Name and registered address of the manufacturer

BMI Group UK Limited, BMI House, 2 Pitfield, Kiln Farm, Milton Keynes, MK11 3LW United Kingdom

Notified Body 1 (Code)

1136

Notified Body 2 (Code)

2137

System/s of AVCP

System 3

Website hosting the DoP

bmigroup.com/uk

Dimensions

Base Unit Of Measure

PCE

Height

0.060 m

Length

1.200 m

Volume

0.043 m³

Width

0.600 m

Insulation characteristics

Base Unit Of Measure

PCE

Compressive strength

150 kPa (@ 10% compression) kPa

Core

Polyisocyanurate (PIR)

Edge profile

Square

Insulant type

PIR (Polyisocyanurate)

Pack size (No. of boards)

8 boards per pack

Thermal conductivity / Lambda (K) W/m·K

0.024 - 0.027 W/m.K (depending on thickness)

Material Characteristics

Durability

The product is designed to last the lifetime of the building

Material Type

Insulation Board

Method of application

Insulation boards should be installed in accordance with the manufacturer’s guidelines.

Membrane Characteristics

Lower surface

Mineral glass tissue

Upper surface

Mineral glass tissue

Safety information

Reaction to fire

Euroclass F in accordance with EN 13501-1

Technical standards and references

CE Marking (harmonised standard(s))

The Certificate holder has taken the responsibility of CE marking the product, in accordance with harmonised European Standard BS EN 13165 : 2012.

Certification

BBA certificate number 23/6935 (PS3).

Codes of Practice

The roof construction and design should comply with BS 6229 (Code of Practice for Flat Roofs with Continuous Supported Coverings).

Designated application

Thermazone Roofboards are intended for use as a thermal insulation layer, and used in conjunction with all types of waterproofing systems, including heat-activated self-adhesive systems and mechanically fixed and adhered single-ply systems.

Relevant standards

EN 12667

Uniclass reference

Pr_25_31_28_65

Weight

Gross Weight

1.779 kg

Unable to find what you were looking for?

Do you have questions about the product, systems or anything else? 
We're here to help - contact us and one of our experts will help you.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.


Thermazone Roofboard is a Polyisocyanurate (PIR) rigid insulation faced on both sides with a mineralised glass tissue.

Key Features

  • Suitable for a range of mechanically fixed and adhered single-ply waterproofing systems

  • PIR core for high thermal conductivity value

  • High compressive strength of ≥ 150 kPa (@10% compression)

Unable to find what you were looking for?

Do you have questions about the product, systems or anything else? 
We're here to help - contact us and one of our experts will help you.